LEAFLET
377.11 KB
Superheated water generator with pressurised combustion and high energy efficiency. Ready for operation in combination with a jet burner on liquid or gas fuel. Furnace with flame reversal and combustion chamber with cooled end plate sized to ensure low heating loads. Range consisting of 7 models with heat outputs from 1,210 to 3,500 kW.

Superheated water generator with pressurized combustion and high energy efficiency, designed for liquid or gas fuel jet burners. Flame-reversal furnace with cooled end plate ensures low heat-load operation. Range includes 7 models with heat outputs from 1,210 to 3,500 kW.
Standard design pressure of 4.9 bar.
Designed and manufactured in compliance with PED Directive 2014/68/EU and applicable pressure vessel regulations.
Deep-penetration welded tube plates with expanded and welded flue connections for enhanced reliability.
Large-dimension furnace designed for low heat-load operation.
Find the perfect model for your needs. Explore the full range with key technical specifications at a glance.
| Feature | Unit | mod.1210 | mod.1400 | mod.1740 | mod.2080 | mod.2350 | mod.2800 | mod.3500 |
|---|---|---|---|---|---|---|---|---|
| Heat output | max | 1210 | 1395 | 1740 | 2080 | 2350 | 2800 | 3500 |
| Heat input | max | 1344 | 1550 | 1933 | 2311 | 2611 | 3111 | 3889 |
Download product manuals, installation guides, and technical data sheets. Additional documents may also be available, including product brochures and ERP labels.
Explore other products from the Ferroli range.

Superheated water generator with three flue passes
Round series
Design pressure: 12 bar or 15 bar (higher pressures on request)
Gas / Oil
6000 to 15000 kW
Up to 200°C (15 bar version)
With 3 effective flue passes

Superheated water generator with three flue passes
Round series
Design pressure: 6 bar or 8 bar
Gas / Oil
6000 to 15000 kW
Up to 175°C (8 bar version)
With 3 effective flue passes

Superheated water generator with three flue passes
Round series
Design pressure: 12 bar or 15 bar (higher pressures on request)
Gas / Oil
1200 to 9000 kW
Up to 200°C (15 bar version)
With 3 effective flue passes

Superheated water boiler with three effective flue passes
Round series
Design pressure: 6 bar or 8 bar
Gas / Oil
1200 to 9000 kW
Up to 175°C (8 bar version)
With 3 effective flue passes

Superheated water generator with three flue passes, two in furnace
Round series
Design pressure: 12 bar (15 bar version available)
Gas / Oil
160 to 3500 kW
Up to 200°C (15 bar version)
With 3 flue passes, two in furnace

Superheated water generator with three flue passes, two in furnace
Square series
Design pressure: 5 bar
Gas / Oil
160 to 1000 kW
Up to 145°C
With 3 flue passes, two in furnace