Hot water generator with pressurised combustion, ready for operation in combination with a jet burner on liquid or gas fuel. Completely cooled combustion chamber, sized to ensure low heating loads. Furnace with flame reversal and low heating load.

Pressurized hot water generator designed for liquid or gas fuel jet burners, featuring a fully cooled combustion chamber. Flame-reversal furnace ensures low heat-load operation and optimized combustion performance.
Steel boiler body insulated with 80 mm high-density glass wool and tear-resistant outer covering, ensuring low heat losses.
Design pressure of 6 bar; higher pressures available on request.
Fully cooled pressurized combustion chamber with optimized return water distribution to prevent thermal stress. Offset burner configuration improves flame reversal, reduces flue gas pressure losses, and expands operating range.
Tube bundle positioned above the furnace to maintain high flue gas temperatures and minimize condensate formation.
Find the perfect model for your needs. Explore the full range with key technical specifications at a glance.
| Feature | Unit | mod.92 | mod.107 | mod.152 | mod.190 | mod.240 | mod.300 | mod.350 | mod.401 | mod.525 | mod.600 | mod.720 | mod.820 | mod.940 | mod.1060 | mod.1250 | mod.1480 | mod.1600 | mod.1890 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Heat output min | kW | 60 | 70 | 100 | 137 | 160 | 196 | 228 | 260 | 341 | 390 | 468 | 533 | 611 | 689 | 813 | 962 | 1040 | 1229 |
| Heat output max | kW | 92 | 107 | 152 | 190 | 240 | 300 | 350 | 401 | 525 | 600 | 720 | 820 | 940 | 1060 | 1250 | 1480 | 1600 | 1890 |
| Heat input min | kW | 64.3 | 75 | 107.3 | 147.4 | 170.9 | 209.5 | 277.5 | 364.5 | 417 | 495 | 502 | 566 | 651 | 731 | 884 | 1046 | 1158 | 1336 |
| Heat input max | kW | 99.5 | 116 | 165 | 206 | 261 | 326 | 378 | 432 | 567 | 648 | 777 | 881 | 1011 | 1140 | 1359 | 1608 | 1736 | 2054 |
Download product manuals, installation guides, and technical data sheets. Additional documents may also be available, including product brochures and ERP labels.
Explore other products from the Ferroli range.

Condensing generator with three flue passes suitable for gas and gasoil
Square series
Design pressure: 6 bar
Up to 106% efficiency
Gas / Oil
65 to 1000 kW
With 3 effective flue passes

Hot water boiler with three flue passes, two in furnace
Round series
Design pressure: 6 bar (higher pressures on request)
Up to 90% efficiency
Gas / Oil
2360 to 6000 kW
With 3 flue passes, two in furnace

Hot water boiler with three flue passes - LOW NOx
Square series
Design pressure: 6 bar
Up to 95% efficiency
Gas / Oil
70 to 3200 kW
With 3 flue passes - Low NOx

Hot water boiler with three flue passes
Round series
Design pressure: 6 bar
Up to 92% efficiency
Gas / Oil
1200 to 9000 kW
With 3 effective flue passes

Hot water boiler with three flue passes
Round series
Design pressure: 6 bar
Exceeding 92% efficiency
Gas / Oil
6000 to 15000 kW
With 3 effective flue passes

Hot water boiler with three flue passes, two in furnace
Square series
Design pressure: 6 bar (higher pressures on request)
Up to 90% efficiency
Gas / Oil
100 to 1480 kW
With 3 flue passes, two in furnace